Mouse CD8 T-cell isolation comes down to three routes. Column-free negative selection (SN4103) labels the non-target cells and pulls them to the tube wall with a magnet; the supernatant is poured off. Column-based negative selection (CBS4103) labels the same populations but separates them in a column held in a magnetic field, so the untouched target cells fall through by gravity. Column-based positive selection (PM008) reverses the logic: an anti-CD8 antibody is coupled directly to the nanobeads, the target cells are captured in the column and eluted once the column leaves the magnet.

Key points

Three routes at a glance

RouteWhat the beads labelSeparationProductBest forCost of the route
Column-free negativeNon-target cells (biotinylated antibody cocktail + streptavidin nanobeads)Magnet, then pour off the supernatantSN4103Spleen, lymph node, bloodThroughput and debris background
Column-based negativeNon-target cells (same cocktail chemistry)Column in a magnetic field, targets drip throughCBS4103Same samples, larger batchesSingle-use column
Column-based positiveTarget cells (anti-CD8 directly conjugated)Column retains targets, elute off-magnetPM008Enzyme-digested tissue; or when only CD8⁺ cells are neededExtra elution step; beads travel with the cells

Four criteria, in order

#QuestionPoints to
1Can the non-target populations be listed completely?Yes → negative selection. No (tumour, liver, heart digests) → positive selection
2How many samples per batch?1–3 → column-free. 10 or more → column-based, run in parallel
3How debris-sensitive is the readout?Low-abundance flow subsets or single-cell sequencing → column-based
4Consumable budget vs. hands-on timeCheapest and shortest → column-free; throughput matters more → column-based

Criteria 1 decides negative versus positive and has nothing to do with purity. Criteria 2 and 3 split the negative routes. If criteria 1 and 2 conflict — a clean sample type but a very large batch — follow criterion 1: batches can be split and scheduled, but no kit fixes a sample whose background populations are not covered by the cocktail.

One clarification worth making: positive selection is not reserved for messy tissue. Spleen and lymph node work fine with PM008, with fewer steps; the reason to choose it is usually “I only want the CD8⁺ cells”, not “my sample is complicated”.

Products used in this note

This page is the English summary. The full article walks through each route step by step — consumables, dosages, volumes, column loading limits, debris handling — with three workflow diagrams, seven comparison tables, a four-criteria decision flow and the limits of each claim: read the full article (Chinese).